Recently Repaired Products
MPR12-BU1
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad Hybrid IC’s, Leaky Capacitors (Open, Corroded Traces)
E0451-521-016
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad Hybrid IC’s, Bad Input Section, Open Resistor(s) Description: OPUS 5000, power supply 5000T
MPS30
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad DC Bus Capacitor(s), Bad Hybrid IC’s, Bad Input Section, Leaky Capacitors (Open, Corroded Traces), May Require Board Replacement
Type: DC power supply unit
Regeneration method: Power regeneration type
Unit capacity: 30kW
Unit generation: First generation
ETU-3MK01Z
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad DC Bus Capacitor(s), Bad Input Section, Bad Output Section, Leaky Capacitors (Open, Corroded Traces)
PSU-20-ACL
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad Hybrid IC’s, Multiple signs of previous repair, Physical Damage
MPS45
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad DC Bus Capacitor(s), Bad Hybrid IC’s, Bad Input Section
Type: DC power supply unit
Regeneration method: Power regeneration type
Unit capacity: 45kW
Unit generation: First generation
MPS45A
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad DC Bus Capacitor(s), Bad Hybrid IC’s, Bad Input Section
Type: DC power supply unit
Regeneration method: Power regeneration type
Unit capacity: 45kW
Unit generation: Second generation (2004 or later)
E0451-521-029
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad Input Section, Bad Output Section, Leaky Capacitors (Open, Corroded Traces), Open Resistor(s)
MPS20
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad DC Bus Capacitor(s), Bad Hybrid IC’s, Leaky Capacitors (Open, Corroded Traces)
Type: DC power supply unit
Regeneration method: Power regeneration type
Unit capacity: 20kW
Unit generation: First generation
MPS60
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad DC Bus Capacitor(s), Bad Hybrid IC’s, Bad Input Section, Leaky Capacitors (Open, Corroded Traces)
Type: DC power supply unit
Regeneration method: Power regeneration type
Unit capacity: 60kW
Unit generation: First generation
MPR5
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad DC Bus Capacitor(s), Bad Hybrid IC’s, Leaky Capacitors (Open, Corroded Traces), Multiple signs of previous repair
Type: DC power supply unit
Regeneration method: Resistor regeneration type
Unit capacity: 5kW
Unit generation: First generation
E0215-541-002
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Failure Info Required for Further Evaluation, Leaky Capacitors (Open, Corroded Traces), Multiple signs of previous repair, Non-supported product - Cannot Test
MPS10
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad Hybrid IC’s
Type: DC power supply unit
Regeneration method: Power regeneration type
Unit capacity: 10kW
Unit generation: First generation
EXP126-0A
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad DC Bus Capacitor(s), Bad Input Section, Bad Output Section, Leaky Capacitors (Open, Corroded Traces)
MPS60B
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad DC Bus Capacitor(s), Bad Hybrid IC’s, Bad Output Section, Physical Damage
MPR10
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad Hybrid IC’s, Bad Input Section, Leaky Capacitors (Open, Corroded Traces)
Type: DC power supply unit
Regeneration method: Resistor regeneration type
Unit capacity: 10kW
Unit generation: First generation
E0451-521-094
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad Output Section, Leaky Capacitors (Open, Corroded Traces)
E0451-521-038
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad DC Bus Capacitor(s), Bad Input Section, Bad Output Section, Leaky Capacitors (Open, Corroded Traces), Open Resistor(s) Description: CPU Power supply, 5000 GHP (10 watts), +5V, +12V, +24V, ISO24V
DC-S1A-2
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad DC Bus Capacitor(s), Bad Regeneration Circuit, Physical Damage
Model Number: DC-S1A
Number of Axes (Part #): 2 (E0451-596-002)
E0451-521-037
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad Fuse, Bad Hybrid IC’s, Bad Input Section, Bad Output Section, Leaky Capacitors (Open, Corroded Traces) Description: OPUS 5000 GLP
DCPS-1-3
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad DC Bus Capacitor(s), May Require Board Replacement, Physical Damage
MPS30B
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad Input Section, Bad Output Section
E0451-680-004
is an
Part of machine
manufactured by
Okuma
Discovered issues:
May Require Board Replacement, Bad Output Section, Leaky Capacitors (Open, Corroded Traces)
MPS45B
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad Hybrid IC’s, Bad Output Section